Hasselblad 201 F Service Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 81
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
CAUTION! When handling the circuit boards a grounded bench mat
and a wrist strap must be used to prevent ESD damage.
Carry out the following checks/adjustments when a camera body is
reassembled after a repair.
Note! Point 1 - 7 without camera shell.
1. The camera body focal length is checked by using the gauge V-2229 together with
the ruler and indicator clock. The focal length is 71.40 mm ± 0.03 mm. Adjustment
slots on the chassis and the bottom mechanism plate.
2.* Secure the camera in the gauge V-2229 by the adapter 904759. Check the 45º
mirror angle with the sighting tube. The image seen, should be symmetrical. Adjust,
if necessary, the four supports in the mirror box by using the tools 901046 (front
supports) and 904018 (rear supports).
3.* Check the flatness of the screen. Use the screen adapter V-4705 and the ruler with
the indicator clock. The same measurement should be obtained at all four corners.
Adjust, if necessary, by the four screws (Pos No. 26, page 14:1).
4.* After the screen is correctly levelled the height must also be checked. Use the
collimator V-4151, the screen adapter V-4705 and the microscope V-2236.
The image seen in the microscope should be the red line central between the two
green lines. Recheck the flatness.
5. Use the tool 902658 or V-2075/2151 for checking of the front key angle. Adjust if
necessary. Cocked position 8° - 9° 3 Ncm. Overtravel 12° - 14° 14 Ncm.
6. Temporarily fit the control panel to the camera body and secure it with a piece of
tape. Use the nut driver 903755 or 903474.
7. Connect the camera body to the Service Test System and go through all checks in the
given order according to the 202 menu. Note! Pos. 7:1 to 7:6 can be checked without
sensor head and light source.
7:1 CAMERA STATUS: Make sure all switches are working properly.
Note! If the contact flex has been removed at any time, the timing between the
pre-release switch (PRS) and the mirror must be checked.
Mount the test shell, 905002, with four screws. Fit the exposure gauge V-2354 in
the release button and slowly rotate the micrometer clockwise and observe when the
mirror is released.
Checks & Adjustments 3:1
Camera body 202FA
Revision 1 February 2000
Link to : VHABSTS
Page view 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 80 81